Home > Blog > Content

What Is The Common Torque Sensor Problems And Troubleshooting ?

Jun 11, 2026

what is the Common Torque Sensor Problems and Troubleshooting ?

 

Shaft-to-shaft rotary torque sensor installation

 

 

Torque sensors are critical components in motor testing systems, dynamometers, industrial automation equipment, and rotating machinery. When a torque sensor malfunctions, the issue is often not caused by the sensor itself but by a combination of electrical, mechanical, installation, parameter, and environmental factors.

This guide explains common torque sensor problems using the framework:

Symptom → Potential Causes → In-Depth Troubleshooting → Corrective Actions → Preventive

 

Recommendations

 

Establishing an Effective Torque Sensor Troubleshooting Framework

A torque sensor measurement system can generally be divided into five layers:

  • Torque sensor unit
  • Power supply or excitation source
  • Signal transmission cables
  • Data acquisition system, instrumentation, or controller
  • Mechanical installation and load interface

When troubleshooting, the most effective approach is to determine whether the problem originates from the sensor, the transmission path, or the measurement system.

Three questions can quickly narrow down the source of the problem:

  • Is there no signal at all, or is the signal inaccurate?
  • Does the problem occur when static, or only during rotation and loading?
  • Did the issue appear immediately after installation, or did it develop after a period of operation?

These symptoms typically correspond to power and wiring issues, installation and calibration issues, or environmental and thermal drift issues.

dynamic-torque-sensor-working-principle

No Signal or Intermittent Signal

No output is one of the most common torque sensor problems and is often misdiagnosed.

Common Causes

  1. Incorrect power supply voltage
  2. Wrong excitation method
  3. Wiring errors
  4. Loose connectors
  5. Broken cables
  6. Poor shielding ground connections
  7. Internal circuit damage

 

In-Depth Troubleshooting

1. Verify Power Supply Specifications

Confirm that the supply voltage and excitation method match the sensor specifications, such as:

5V

12V

24V

±15V

2. Check Actual Voltage at the Sensor

Use a multimeter to verify that power is reaching the sensor connector. Power available in the control cabinet does not necessarily mean power is available at the sensor.

3. Inspect Connectors and Cables

Look for:

  1. Oxidized connector pins
  2. Poor terminal crimping
  3. Broken conductors caused by repeated cable flexing

4. Test Signal Channels Individually

For combined speed and torque sensors, verify each output channel independently.

 

Typical Diagnosis

If the sensor performs normally during bench testing but loses signal after installation, the likely causes are:

Wiring

Connectors

Power supply

Instrument settings

rather than the sensor itself.

Significant Fluctuation or Unstable Readings

Signal fluctuations, jitter, and random spikes are among the most challenging field issues.

Common Causes

  • Electromagnetic interference (EMI)
  • Poor grounding
  • Mechanical vibration
  • Shaft misalignment
  • Mechanical preload
  • Improper sampling or filtering settings

 

EMI Sources

Variable frequency drives (VFDs)

Motors

Servo drives

Installation-Related Issues

Shielding not grounded at a single point

Signal cables routed alongside power cables

Coupling misalignment

Excessive mechanical vibration

 

In-Depth Troubleshooting

Separate Signal and Power Cables

Route sensor cables away from power cables.

If necessary, use:

Ferrite cores

Filters

Differential signal acquisition

Verify Mechanical Alignment

Check:

  • Coaxiality
  • Face runout
  • Axial clearance
  • Angular misalignment
  • particularly in high-speed rotating applications.

Identify Interference Patterns

If signal fluctuations occur in sync with motor startup, shutdown, or VFD switching frequencies, EMI is likely the root cause.

Optimize Sampling and Filtering

Avoid:

Excessive filtering that masks real data

Insufficient filtering that allows noise to dominate

EV motor dynamometer testing system

Zero-Point Drift or Failure to Return to Zero

Zero-point issues typically fall into two categories:

Temporary zero shift without sensor damage

Permanent shift caused by overload or damage

Common Causes

Residual torque after shutdown

Mechanical preload during installation

Temperature variation

Overload-induced deformation

Internal circuit changes

 

In-Depth Diagnosis

A practical method is to remove the sensor from the system and check the zero point independently.

If the Zero Point Returns to Normal

The issue is likely caused by:

Installation stress

Structural loading

Shutdown positioning

If the Zero Point Remains Abnormal

The sensor may have experienced:

Overload

Mechanical damage

Internal electronic failure

Prevention Recommendations

Select a torque range with sufficient safety margin

Consider 1.5 to 2 times the maximum operating torque

Account for startup shock loads and temperature rise

Recalibrate the zero point after maintenance

 

Large Measurement Errors, Poor Linearity, and Poor Repeatability

The key issue here is not whether a signal exists, but whether the measurement is trustworthy.

Common Causes

Incorrect instrument range settings

Sensitivity mismatch

Wrong signal interpretation

Installation errors

Mechanical transmission losses

Parameter-Related Issues

Examples include:

Incorrect mV/V settings

Wrong frequency scaling

Incorrect CAN bus parsing parameters

Mechanical Factors

Friction losses

Backlash

Drive efficiency variations

These may be incorrectly interpreted as sensor errors.

 

In-Depth Troubleshooting

Verify Raw Sensor Output

Disconnect downstream instruments and inspect the sensor's raw output signal.

Perform Multi-Point Verification

Use standard loads or calibration equipment to determine whether the error is:

Constant offset

Proportional error

Nonlinearity

For Frequency Output Torque Sensors

Verify:

Zero frequency

Full-scale frequency

LC parameters

 

Failure to Return to Zero After Loading and Overload Damage

Overload can cause permanent damage to the sensor structure.

Typical Symptoms

Failure to return to zero

Full-scale signal distortion

Increasing error during repeated loading

Intermittent signal loss

Open-circuit behavior

How to Assess Overload Damage

Investigate whether any of the following events occurred:

Mechanical jamming

Emergency stop

Shock loading

Reverse impact loading

Determine whether measurement issues began after a specific event.

This event correlation is often critical for diagnosis.

Perform Verification Tests

Conduct:

No-load zero-point testing

Standard load testing

If abnormalities remain under no-load conditions, sensor damage is highly likely.

Corrective Action

When overload damage is confirmed:

Replace the sensor

Return the sensor for factory repair

Recalibration can correct parameter-related issues but cannot repair material deformation or structural damage.

 

Environmental and Installation Issues

Many torque sensor failures appear to be electrical problems but are actually caused by installation or environmental conditions.

Common Environmental Factors

Moisture

Oil contamination

Metal dust

Corrosion

Excessive vibration

Temperature gradients

Frequently Overlooked Installation Problems

Cable Management Issues

Excessively small cable bend radius

Repeated cable flexing

Internal conductor fatigue

Connector Contamination

Water vapor

Cutting fluid

Increased contact resistance

Mechanical Installation Problems

Uneven mounting surfaces

Uneven bolt preload

Housing deformation due to stress

Incorrect Protection Rating

The sensor protection level may not match the operating environment, especially in:

High humidity conditions

Dusty environments

Heavy oil mist environments

Electric motor efficiency measurement

Recommended Torque Sensor Troubleshooting Sequence

For efficient field troubleshooting, follow this sequence:

Step 1: Observe Symptoms

Identify whether the problem is:

No signal

Drift

Erratic readings

Large deviation

Failure to return to zero

Step 2: Check Power Supply

Verify:

Voltage

Excitation

Polarity

Ripple

Step 3: Check Connections

Inspect:

Connectors

Cables

Shielding

Grounding

Continuity

Step 4: Check Mechanical Installation

Evaluate:

Coaxiality

Preload

Couplings

Vibration

Shock loads

Step 5: Verify Parameters

Review:

Measurement range

Sensitivity

Zero-point settings

Filters

Alarm thresholds

Step 6: Evaluate Environmental Conditions

Check for:

EMI

Temperature fluctuations

Humidity

Oil contamination

Corrosion

Step 7: Assess Sensor Integrity

Only after all previous checks should the sensor itself be considered the source of failure.

 

Engineering Prevention Recommendations

The most effective maintenance strategy is preventing failures before they occur.

Best Practices

Select a sensor with sufficient safety margin.

Avoid continuous operation near full-scale capacity.

Route signal cables independently from power cables.

Separate high-voltage and low-voltage wiring.

Ground cable shielding correctly.

Ensure proper coaxial alignment during installation.

Maintain mechanical rigidity and vibration isolation.

Perform periodic calibration and zero-point verification.

Keep historical records of measurement trends.

Record operating conditions, temperature, rotational speed, startup events, and braking events when investigating intermittent problems.

Proper installation, regular inspection, and systematic troubleshooting significantly improve torque sensor reliability and measurement accuracy.

Torque ripple measurement during motor testing

 FAQ

Why does my torque sensor have no output signal?

The most common causes include incorrect power supply voltage, wiring errors, loose connectors, broken cables, poor grounding, or incorrect instrumentation settings.

 

What causes unstable torque sensor readings?

Unstable readings are often caused by electromagnetic interference (EMI), grounding issues, mechanical vibration, shaft misalignment, improper cable routing, or unsuitable filtering settings.

 

Why does a torque sensor fail to return to zero?

Zero-point drift can result from residual mechanical stress, installation preload, temperature changes, overload conditions, or internal sensor damage.

 

How can I determine whether a torque sensor is damaged?

Remove the sensor from the system and perform a no-load test. If the zero point remains abnormal and standard load tests fail, sensor damage is likely.

 

Can recalibration fix overload damage?

No. Recalibration can correct parameter-related errors but cannot repair permanent mechanical deformation or material damage caused by overload.

 

How do I reduce electrical noise in torque sensor signals?

Separate signal cables from power cables, use proper shielding and grounding, install ferrite filters if necessary, and verify that EMI sources such as VFDs are not interfering with the signal.

 

What is the most common installation mistake for torque sensors?

Poor shaft alignment, excessive preload, uneven mounting surfaces, and improper coupling installation are among the most common installation-related causes of measurement errors.

 

How often should torque sensors be calibrated?

Calibration intervals depend on operating conditions and accuracy requirements. Regular verification of zero points and calibration values is recommended as part of preventive maintenance.

 

Can temperature affect torque sensor accuracy?

Yes. Temperature changes can cause zero-point drift, sensitivity changes, and measurement errors, especially in systems with inadequate temperature compensation.

 

What safety margin should be considered when selecting a torque sensor?

A torque sensor is typically selected with a full-scale range approximately 1.5 to 2 times greater than the maximum expected operating torque to accommodate shock loads and long-term reliability.

 

Torque Sensor

Send Inquiry