Magnetostrictive Ultrasonic Transducer

Magnetostrictive Ultrasonic Transducer

• Fully sealed structure, robust and durable • Non-contact measurement, never wear • Absolute position output without zeroing • Nonlinearity, ±0.01%F.S of full scale • Repeatability, ±0.001%F.S of full scale • Optional zero to full
Send Inquiry
Description

RSserial Magnetostrictive Linear Displacement Transducer

 

 

Technical Characteristics

  • Here's a simplified and relatable explanation of the features you mentioned, with examples:

    1. Rugged and fully enclosed design
    - *What it means:* The device is built tough and sealed tightly, so dust, water, or rough handling won't damage it.

    2. Non-wear, non-contact measurement method
    - *What it means:* It measures things without touching them, so nothing wears out over time.

    3. Low power consumption design effectively reduces system heating
    - *What it means:* It uses very little energy, so it doesn't get hot.

    4. Absolute position output, not affected by power failure
    - *What it means:* Even if the power goes out, it remembers the exact position when power comes back.

    5. Adapt to harsh environment, IP68 protection level
    - *What it means:* It can handle extreme conditions like dust, dirt, and being underwater for long periods.

    6. Multiple interfaces are available: Analog, SSI, Modbus
    - *What it means:* It can connect to different types of systems, making it flexible for various uses.
     

334e594d3b20d18faefb1bb749ee7cd

Technical parameter 

 

 

Measurement data: position magnet ring

 

Power consumption: < 100mA

 

Effective itinerary: 25 ~ 5500mm (customized according to customer needs)

 

Polarity protection: Maximum-30Vdc

 

Current: 4 ~ 20mA or 0 ~ 20mA (min/max load 0/500 Ω)

 

Overpressure protection: Maximum 36Vdc

 

Voltage:-5 ~ 5Vdc or-10 ~ 10Vdc (minimum load resistance ≥ 10KΩ)

 

Insulation resistance: > 10MΩ

 

Nonlinearity: < ± 0.02% of full scale, minimum ± 50μm

 

Insulation strength: 500V

 

Repeat accuracy: < ± 0.001% of full scale or equal to resolution

 

Electronic bin: 304L stainless steel

 

Resolution: 16-bit D/A, minimum 5μm

 

Measuring rod: 304L stainless steel/316L stainless steel

 

Magnet ring speed: arbitrary

 

Position magnets: various ring magnets

 

Protection level: IP68 in straight line mode/IP67 in socket mode

 

Installation direction: Any direction, thread installation (thread specification is optional)

 

Working temperature:-40℃ ~ + 75℃

 

Outgoing mode: straight-out cable or aviation plug (M16 connector)

 

Input voltage: + 24Vdc ± 20%/+ 12Vdc ± 20%

 

Non-usable area at head and end: 50.8 mm+63. 5mm (customizable)

 

 

 

Dimension 

 

dimension

 

RS

 

 

Non-contact Design

 

The magnetic ring and measuring rod employ a contactless measurement principle, eliminating mechanical wear and acoustic noise during operation. This friction-free design minimizes component degradation, reduces maintenance requirements, and enhances long-term reliability.

20250421115443
20250421115348

Modular circuit

 

With its modularized internal circuitry, the electronic compartment enables easy servicing and offers broad adaptability for diverse system integrations.

Strong adaptability

 

The device operates reliably under extreme environmental conditions, including temperature extremes, humidity, vibration, mechanical shock, corrosive elements, and particulate contamination.

20250421115454

 

Principle structure diagram

 

2025-09-28095224236

 

Installation 

 

Cylinder Application Notes


Cylinder Installation - The pressure-resistant round tube housing sensor is usually installed inside the cylinder, and the installation thread specifications include: M18X1.5, M20X1.5, 3/4"-16UNF-3A. Before installation, you need to make sure that the cylinder has been processed according to the correct size given in the atlas.


Mechanical Installation - The sensor has no requirements for the installation position and direction, but it must be installed firmly and reliably. The position magnet is installed on the moving part to be measured and maintains an appropriate distance from the measuring rod
Position Magnet - To ensure the accuracy of the measurement, the mounting bracket of the position magnet must be made of non-magnetic materials, such as screws, magnetic isolation gaskets, etc.

installation

 

 

How to select sensor range according to oil cylinder ?


When selecting sensor range for existing oil cylinder, ensure that the sensor range includes the oil cylinder piston rod stroke, that is, the sensor range 0 point is before the piston rod stroke begins, and the sensor range end point is after the piston rod stroke ends.

 

Application 

 

3

Bridge monitoring

Cylinder

Static level

Chemical industry

 

 

 
why choose us ?

 

Global Shipping

We ship worldwide with fast and secure logistics door to door . We can send by air express and by cargo 

Long Warranty

Our products come with an extended warranty, ensuring reliability and long-term satisfaction.

24H Online Service

Our support team is available 24/7 to assist with inquiries, orders, or after-sales service.

Competitive Price

We offer high-quality products at factory-direct prices, saving you cost without compromising quality.

 

certificates
 
 

Official certification

2

Certificate 

CE

Certificate 

ROHS00

Certificate 

1

Certificate 

Rohs

Certificate 

 

 

FAQ

Q: what is the lead time ?

A: Normally the lead time is about 7-15 days.

Q: Can you customize according to customer's request ?

A: yes , if you provide the drawing and some detials , then we can customize the new ones for you.

Q: How can you arrange delivery ?

A: For small quantity , we can send by air express ,such as DHL, UPS, Fedex . For big quantity , we can arrange delivery by sea cargo .

Q: About samples:

A: Yes, we can make samples for you . But it is not free.

Q: About guarantee:

A: 12 months 

 

 