Home > Blog > Content

Magnetostrictive Displacement Sensor Vs LVDT: Key Differences And Selection Guide

Sep 28, 2026

Magnetostrictive Displacement Sensor vs LVDT: Key Differences and Selection Guide

 

The most practical difference between a magnetostrictive displacement sensor and an LVDT is their typical application range. A magnetostrictive type is generally more suitable for medium- to long-stroke absolute position feedback, especially in hydraulic cylinders and injection molding machines. An LVDT displacement sensor is generally more suitable for short-stroke, small-displacement, or rapidly changing measurements.

Both technologies can operate without sliding electrical contact inside the sensing mechanism. However, "non-contact" does not mean that the sensor requires no connection to the moving part during installation. A magnetostrictive sensor requires a position magnet to be fixed to or move with the measured component, while an LVDT requires its core to move with the measured component.

 

magnetic sensor

 

Magnetostrictive Displacement Sensor vs LVDT: Main Differences

 

Dimension Magnetostrictive Displacement Sensor LVDT Displacement Sensor
Measurement principle A position magnet interacts with the magnetic pulse field in the waveguide and generates a strain wave. Position is determined according to the propagation time. An AC excitation is applied to the primary coil. Moving the core changes the differential output of the two secondary coils.
Moving component Usually a magnetic ring or U-shaped magnet that moves with a piston or slide Usually an iron core mechanically connected to the measured component; probe-type versions may use a spring-loaded probe to contact the workpiece
Stroke characteristics Product selections cover millimeter-level to several-meter strokes, making them convenient for long-stroke feedback Particularly suitable for short-stroke precision measurement; longer-stroke versions are also available, so they should not simply be described as limited to a few millimeters
Position and power loss Directly measures the absolute position of the magnet. After power is restored, returning to zero is normally not required Core position corresponds to a continuous output and is not an incremental encoder. Whether zeroing is required depends on the signal conditioner and the equipment reference setting
Signal processing Most industrial products include built-in electronic circuits and provide analog outputs or industrial communication according to the model A bare AC-LVDT requires AC excitation and demodulation; a DC-LVDT with integrated signal conditioning can provide a direct DC output
Dynamic measurement The update rate related to stroke length and the controller communication cycle should be checked The bandwidth of the complete system, including excitation, demodulation, and filtering, should be checked; the sensing principle alone cannot determine which technology is always faster
Installation considerations Magnet gap, surrounding ferromagnetic materials, dead zones at both ends, and mechanical clearance between the sensing rod and moving component Coaxial alignment between the core and coil, keeping the core within the specified linear range, and avoiding lateral forces in the connection mechanism

The principles, stroke ranges, and interfaces depend on the specific product. For example, TE describes LVDTs with both free-core and guided-probe structures, while Temposonics lists magnetostrictive rod-style models covering 25–7620 mm. These are examples of product ranges and should not be considered universal specifications for all models.

 

lvdt linear position sensors

 

How to Choose Between a Magnetostrictive Position Sensor and LVDT?

Position Feedback for Hydraulic Cylinders

For full-stroke hydraulic cylinder feedback, a magnetostrictive position sensor should generally be evaluated first. The magnet can move with the piston while the sensing rod is inserted into the piston-rod bore.

However, the cylinder structure must first be checked to confirm whether an installation hole can be machined and whether the flange sealing, pressure rating, rod diameter, and end-space requirements are suitable.

If an existing hydraulic cylinder is already equipped with an LVDT, or if there are special requirements such as high temperature or high pressure, an LVDT should not automatically be excluded simply because the application is industrial. TE also lists structures designed for in-cylinder and high-pressure applications.

Injection Molding Machines and Long-Stroke Slides

For injection molding machine mold-opening positions and long-stroke slides, compare the effective stroke, update cycle, output interface, and installation space of a magnetostrictive displacement sensor.

For an externally mounted design, the magnet must move along the specified path of the sensor. The mounting bracket should also be stable enough to prevent changes in the magnet gap caused by deformation.

Workpiece Measurement and Small Displacement

For workpiece dimensional measurement, small valve-core displacement, and small deformation measurement on test benches, a short-stroke LVDT displacement sensor should generally be evaluated first, particularly a guided-probe or free-core design.

If the contact force of a probe could affect the measured object, a free-core structure and its connection method should be considered instead of comparing only the nominal resolution.

What to Check Before Ordering

1. Convert the Stroke Into a Complete Dimensional Chain

For a magnetostrictive displacement sensor, the head-side zero zone and end dead zone must be considered in addition to the effective measuring stroke.

For an LVDT, check whether the specified stroke is expressed as ±stroke or total stroke, and make sure the mechanical limits cannot push the core outside the linear range.

2. Compare the Complete Error Budget

Do not compare sensors based only on resolution.

The comparison should also include linearity error, repeatability, temperature effects, installation errors, and signal-conditioner noise.

The "theoretically infinite resolution" sometimes associated with an LVDT does not mean that the complete measurement system has infinite accuracy.

3. Check Actual Speed and Control Cycle

The actual sensor response and controller cycle should be considered together.

For example, one Temposonics EtherNet/IP model specifies a cycle time of 1 ms for strokes up to 2000 mm and 2 ms for strokes up to 4800 mm. Other stroke lengths and interfaces should be checked against the specifications of the corresponding model.

For an LVDT, the complete system should be evaluated together with the filtering and response characteristics of its signal conditioner.

4. Check Materials and Installation Tolerances

For a magnetostrictive position sensor, the magnet should not be placed arbitrarily close to ferromagnetic materials. The referenced model also specifies minimum distances between the magnet and the cylinder head or piston.

For an LVDT, the main considerations are preventing eccentricity, sticking, and lateral loading of the connection rod.

When the sensor operates in humid, dusty, or oil-filled environments, the appropriate sealing structure should be selected according to the application.

Magnetostrictive Displacement Sensor vs LVDT: Final Selection

A practical engineering rule can be used as an initial screening method:

For relatively long-stroke absolute position measurement in hydraulic cylinders or mechanical shafts, evaluate a magnetostrictive displacement sensor first. For short-stroke measurement of small changes, evaluate an LVDT displacement sensor first.

The final selection should still be based on the installation dimensions, complete system error budget, dynamic response, and signal interface.

Neither technology should be considered universally superior to the other. The appropriate choice depends on the actual application and the complete measurement system.

 

fAQ

1. What is the main difference between a magnetostrictive displacement sensor and an LVDT?

A magnetostrictive displacement sensor is generally more suitable for medium- to long-stroke absolute position feedback, especially in hydraulic cylinders and injection molding machines. An LVDT displacement sensor is generally more suitable for short-stroke, small-displacement, or rapidly changing measurements.

 

2. Is a magnetostrictive displacement sensor better than an LVDT for hydraulic cylinders?

For full-stroke hydraulic cylinder position feedback, a magnetostrictive displacement sensor should generally be evaluated first. However, an LVDT can also be used in hydraulic cylinder applications, including in-cylinder and high-pressure structures. The final choice depends on installation dimensions, pressure requirements, system accuracy, dynamic response, and interface.

 

3. Can an LVDT displacement sensor measure long strokes?

Yes. LVDTs are particularly suitable for short-stroke precision measurement, but longer-stroke models are also available. Therefore, an LVDT should not simply be considered a sensor limited to a few millimeters of measurement.

 

4. Does a magnetostrictive displacement sensor require the moving part to contact the sensor?

The sensing mechanism does not require sliding electrical contact. However, installation still requires a position magnet to be fixed to or move with the measured component. Therefore, "non-contact" does not mean that the moving component has no mechanical relationship with the sensor installation.

 

5. Does an LVDT require the moving part to contact the sensor?

An LVDT normally uses a moving iron core that is mechanically connected to the measured component. Probe-type LVDTs can use a spring-loaded probe to contact the workpiece. The appropriate structure depends on the measurement application and connection method.

 

6. Which sensor should be considered for short-stroke displacement measurement?

For workpiece dimensional measurement, small valve-core displacement, and small deformation measurement, a short-stroke LVDT displacement sensor should generally be evaluated first, particularly a guided-probe or free-core design.

 

7. What should be checked before selecting a magnetostrictive displacement sensor or LVDT?

The main factors include measurement stroke, installation dimensions, linearity error, repeatability, temperature effects, installation errors, signal-conditioning requirements, dynamic response, control cycle, and output interface. For magnetostrictive sensors, magnet gap and surrounding ferromagnetic materials should also be checked. For LVDTs, coaxial alignment and lateral forces on the connection mechanism are important considerations.

 

8. Do magnetostrictive displacement sensors and LVDTs require zeroing after power is restored?

A magnetostrictive displacement sensor directly measures the absolute position of the magnet, so returning to zero is normally not required after power is restored. An LVDT provides a continuous output corresponding to core position and is not an incremental encoder. Whether zeroing is required depends on the signal conditioner and the equipment reference setting.

 

9. Which is faster, a magnetostrictive displacement sensor or an LVDT?

The sensing principle alone cannot determine which technology is always faster. For a magnetostrictive displacement sensor, the update rate related to the stroke and the controller communication cycle should be checked. For an LVDT, the excitation, demodulation, filtering, and complete system bandwidth should be considered.

 

10. Should resolution be the main factor when comparing an LVDT with a magnetostrictive displacement sensor?

No. Resolution should not be considered alone. Linearity error, repeatability, temperature effects, installation errors, signal-conditioner noise, dynamic response, and the complete system error budget should also be considered when selecting between the two technologies.

Send Inquiry