Home > News > Content

Magnetostrictive Level Sensor in Storage Tank Level Measurement

Aug 16, 2023

Magnetostrictive Level Sensor in Storage Tank Level Measurement

 

Magnetostrictive Level Gauge for Storage Tanks

A magnetostrictive level gauge is a high-precision continuous liquid level sensor designed for storage tanks, underground tanks, and industrial process vessels. It measures liquid level through the interaction between a float's magnetic field and a pulse traveling along a waveguide wire, providing stable and accurate level measurement for industrial automation and inventory management.

Technical data indicates that magnetostrictive level gauges are suitable for continuous liquid level measurement, interface level measurement, and integration with PLC, DCS, and SCADA systems.

magnetostrictive-level-gauge-storage-tank

 

How Does a Magnetostrictive Level Gauge Work?

The working principle of a magnetostrictive level gauge can be summarized as:

Float + Waveguide Wire + Time Measurement

The electronic module sends an electrical pulse through the waveguide wire, generating a magnetic field as the pulse travels. When this magnetic field encounters the permanent magnet inside the float, a torsional wave is generated at the float's position.

The torsional wave then travels back to the sensor at a constant speed. By measuring the time between the transmitted pulse and the returning wave, the instrument accurately determines the float position, which directly represents the liquid level.

This process is similar to measuring the return time of an echo. Since the propagation speed remains constant, higher timing precision results in higher level measurement accuracy.

Technical specifications indicate that many magnetostrictive level gauges achieve approximately 1 mm accuracy, with some models providing even higher precision.

 

Why Magnetostrictive Level Gauges Are Suitable for Storage Tanks

For storage tank level measurement, the primary requirements are continuous monitoring, long-term stability, and easy integration into industrial control systems.

A magnetostrictive level gauge is particularly suitable for:

Continuous liquid level monitoring

Inventory gauging

Tank farm management

Liquid-liquid interface measurement (such as oil-water interfaces)

Its advantages in storage tank applications include:

Continuous level signal output after installation

Easy integration with PLC, DCS, and SCADA systems

High accuracy suitable for custody transfer, metering, and process control

Simple mechanical structure with relatively low maintenance requirements

Installation through existing tank-top openings, making it suitable for underground tanks and tanks already in operation while reducing retrofit costs

Industrial oil storage tanks using continuous liquid level monitoring systems

 

Common Applications of Magnetostrictive Level Gauges

Magnetostrictive level gauges are widely used in industrial sectors including:

Petroleum

Chemical processing

Pharmaceutical manufacturing

Food and beverage

Water treatment

Underground storage tanks at oil depots and gas stations

Typical applications include:

Inventory Management

Accurately monitor storage tank inventory levels while reducing the risk of overflow or stock shortages.

Process Control

Provide real-time liquid level data to pumps, valves, and interlocking systems.

Interface Measurement

Measure phase interfaces such as oil-water separation or light-liquid/heavy-liquid interfaces.

Underground Storage Tanks

Install through existing tank openings without interrupting normal operations.

Irregular Tank Shapes

Use linearization functions or volume tables to improve level-to-volume conversion accuracy.

Magnetostrictive Level Gauge Installation Methods

The most common installation method is top mounting.

The probe rod is inserted into the tank through a flange, threaded connection, or existing nozzle located at the top of the tank. Depending on the product design and tank configuration, some models may also support installation on magnetic level gauges or side mounting.

Installation Considerations

Ensure sufficient clearance for unrestricted float movement.

Verify that the probe length covers the required measuring range.

Match the float with the density of the measured medium.

Avoid excessive turbulence, agitation, or internal obstacles that may interfere with float movement.

Confirm material compatibility and explosion-proof certification for high-temperature, high-pressure, corrosive, or hazardous environments.

Top-mounted magnetostrictive level gauge installed through the storage tank

Advantages and Limitations of Magnetostrictive Level Gauges

Advantages

High measurement accuracy suitable for custody transfer and metering applications

Excellent repeatability and long-term stability

Multiple output options for industrial automation integration

Capable of liquid-liquid interface measurement

Limitations

Performance depends on proper float selection according to liquid density

Not ideal for highly viscous, crystallizing, adhesive, or particle-containing media

Severe turbulence or agitation may affect signal stability

Measuring range is limited by the probe structure and is generally less suitable than radar for extremely long-range or non-contact applications

How to Select a Magnetostrictive Level Gauge

When selecting a magnetostrictive level gauge for an engineering project, the following parameters should be evaluated:

Medium density to ensure proper float operation

Operating temperature and pressure, especially for chemical and oil & gas storage tanks

Measurement range, including installation allowance

Output signal, such as 4–20 mA, HART, Fieldbus, or Modbus

Installation interface, including flange type, thread specification, and insertion depth

Explosion-proof and ingress protection ratings for hazardous environments

Interface measurement requirements, particularly for oil-water separation applications

For high-precision inventory gauging, magnetostrictive level gauges are generally an excellent solution. However, for applications involving very large tanks, non-contact measurement, heavy foam, excessive vapor, or numerous internal obstructions, radar-based solutions may sometimes provide greater reliability.

Industrial Magnetostrictive Level Transmitter

Typical Storage Tank Application Example

Consider a diesel storage tank that requires continuous 24-hour liquid level monitoring with data transmitted to a SCADA system.

A magnetostrictive level gauge is installed through an existing opening at the top of the tank. As the diesel level changes, the float moves accordingly, and the instrument continuously outputs a real-time liquid level signal.

If inventory volume calculation is required, the system can perform linearization or volume conversion using a tank capacity table.

If oil-water separation occurs inside the tank, the same instrument can simultaneously measure the interface level, making it highly practical for oil depots and chemical storage facilities.

Magnetostrictive Level Gauge vs Other Level Gauges

Compared with other liquid level measurement technologies:

It provides higher accuracy than conventional float-type level gauges and is better suited for automated control systems.

It is better suited than ultrasonic level gauges for certain applications involving volatile liquids, low dielectric constants, or vapor-heavy environments.

Compared with radar level gauges, it is more dependent on matching the float with the measured medium, while offering an excellent balance of accuracy and cost for many standard storage tank applications.

Industrial Magnetostrictive Level Transmitter

Conclusion

A magnetostrictive level gauge measures liquid level using the interaction between a float's magnetic field and a pulse traveling along a waveguide wire. Its combination of high accuracy, continuous measurement, excellent repeatability, and automation compatibility makes it well suited for storage tanks, underground tanks, inventory management, process control, and interface measurement.

When selecting a system, engineers should carefully evaluate the medium density, operating conditions, installation requirements, measurement range, output signal, and environmental certifications to ensure reliable long-term performance.

Send Inquiry